DETERMINATION OF NAPTHALENE IN TAR & BITUMEN - AS PER IS : 1219
AS PER IS - 1219.
APPARATUS FOR DETERMINATION OF PHENOL-IS 1218
The apparatus consist of Phenol Flask, a Beaker of suitable size, Separating funnel with stopper, a Glass Thermometer of 0-100 deg C or similar range but without chemicals or reagents
APPARATUS FOR DISTILLATION OF CUT BACK BITUMEN - IS 1213
The distillation of cutback asphalt, according to IS 1213 and ASTM D402, is a test to determine the proportions of volatile components in cutback asphalt by distilling off the volatile fractions at specified temperatures. This process helps to understand the composition and stability of the cutback asphalt in terms of the amount of volatiles present. Complete with one distillation flask of 500ml. capacity and one 100 ml. crow receiver Electrically heated model with Energy regulator.
HORIZONTAL BURNING APPARATUS FOR THERMAL INSULATION AS PER IS 11239 PART 12
The Indian Standard IS 11239 (Part 12): 1988 outlines the method for assessing the horizontal burning characteristics of rigid cellular thermal insulation materials. This test evaluates the material's flammability when exposed to a low-energy heat source. The Equipment as per ASTM D635 /ISO 9772 / UL 94 can also be supplied.
COPPER CUM SILVER CORROSION BATH - ASTM D130, IP 227
Complies with - IP 154 & IS 1448 (P 15), ASTM D 130, IP 227, ASTM D4814.
ULTRA LOW TEMP. KINEMATIC VISCOSITY BATH - (-40˚C) - COMPLETE S.S.
Suited for 4 Viscometer at a time. Compliance with ASTM D445, IS 1448 (P 25).
ROUND JAR KINEMATIC VISCOSITY BATH-(ABOVE AMBIENT)-FOR 4 VISCOMETERS
This equipment is used to determine the kinematic and intrinsic viscosity of fuels, lubricants, and petrochemical raw materials at constant temperatures, following ASTM D 445 and similar methods. It features a 4-test bath with a round glass vessel, a digital temperature controller with dual display, and a PT-100 sensor. The temperature range is from 5°C above ambient to 150°C with ±0.5°C accuracy. It includes a motorized stirrer, a lighting attachment, and a universal viscometer holder. The system operates on 230V single phase. Glass U-tube viscometers are available separately.
ENVIRONMENTAL CHAMBER FOR CREEP TENSILE TESTING - ASTM D6992
As per ASTM D6992,Environmental Chamber is designed to provide precise temperature control for creep tensile testing. It ensures accurate and reliable testing conditions for assessing material behavior under varied environmental influences. The chamber's robust construction and user-friendly features support consistent performance and easy integration with your testing equipment.
DETERMINATION OF RESISTANCE TO THERMAL SHOCK ON GLASSWARE
AS PER IS 6506.1972(R.A.2017) - Hot and Cold Water method. This method applies to all kinds of glass containers for pharmaceutical use, whose test temperature difference is less than 100℃. Apparatus as IS:11930(ISO 7459) also available
GO-NOGO HEIGHT GAUGE - FOR BOTTLES
Go/No-Go gauges are precision tools used in quality control to verify whether a glass bottle's dimensions, such as height, fall within specified tolerances. These gauges provide a simple pass/fail assessment, ensuring that each bottle meets the required standards.
SILVER STRIPS-FOR SILVER CORROSION TEST-IP 227
SILVER STRIPS-FOR SILVER CORROSION TEST-IP 227: 18mm L x 12.5mm W x 3mm T