NABL Accredited Calibration Laboratory

ORBITAL SHAKING INCUBATOR - GMP - HEATING & COOLING - 5000 ML X 6 FLASKS - WITH PLC, HMI & 21-CFR SOFTWARE

Model Number : EIE-203RDG6X5000

Double walled, Outer chamber made of S.S.304, Inner made of S.S.316, Temp. Range from 5°C to 60°C. Temp.resolution 0.1°C, Temp.control accuracy 1°C, PMDC Motor with thyristor drive, Interior illumination with glass viewing window, Shaking speed from 50-200 RPM, equipped with Digital RPM Indicator, Digital Timer, Digital Temp.controller to work on 230 V AC Single Phase.

ORBITAL SHAKING INCUBATOR TYPE

Construction Details:

  1. Electrical wiring as per CE Compliance
  2. Chamber equipped with PLC & Touch screen HMI system
  3. Highly accurate Individual control Loop for precise control of temp and humidity
  4. Interior fabricated from Mirror Polished Stainless Steel (S.S.-304 Grade).
  5. Exterior body is also fabricated from Stainless Steel material, (S.S.-304 Grade)
  6. Toughened glass window to inspect samples without affecting the chamber temperature.
  7. Sponge type silicon gasket for air-tight sealing to avoid leakage of chamber uniformity
  8. Electrical wiring as per CE Compliance
  9. Chamber illumination by LED light with door switch.
  10. User friendly and tactfully designed chamber door and locking mechanism
  11. Aesthetic outer appearance and high quality
  12. Unit mounted on castor wheels for easy movement.
  13. Supplied complete with IQ, OQ, DQ, PQ Qualifications documents and Instruction manuals.

Following advance features are available:

  1. Equipped with 7" Touch screen HMI Controller and PLC System
  2. Equipped with Magnetic Door Lock Mechanism 
  3. Password protected door access system
  4. Supplied complete with 21-CFR (PART-11) Compliance PC Software
  5. Audit trail generation in PC Software
  6. Auto resume after power failure
  7. Provision for In-Built Data logger (Uniformity module) system
  8. Provision for 4 Temp Sensor for data logging purpose

Salient Features of 21-CFR Compliance Software:

  1. Multi Chamber data - Acquisition Software
  2. Generates graphical analysis of DATA as per - 21 CFR Compliance guidelines
  3. File encryption Facility
  4. Secure login facility
  5. Password protected. System access is controlled by the system supervisor
  6. Limit system access
  7. Limit module access
  8. Password expiration
  9. Bilateral user ID and password identification
  10. Access failure lock out
  11. System access logs
  12. System audit trail report.
  13. System Input / Output logs
  14. Mean kinetic temperature calculation
  15. Maintains log of user activities like users logged in, login/logout time, and changes made by the user in software settings Audit Trail Reports.
  16. Ensure Gap-free Records
  17. Schedule Reports via Email
  18. Meet Tough Standards
  19. View Environments in Real-Time
  20. Flexible Alarm Management
  21. Consistent Alarm Acknowledgements
  22. Highly Secure & Temper proof
  23. Protection From Data Loss

Air Circulation:

Temperature is maintained by a quiet running blower circulation throughout the chamber. Forced air circulated vertically down and re-circulated throughout the chamber for uniform temperature and humidity distribution.

Heating & Cooling System:

  1. Long lasting SS tubular heaters used as heating element. The stainless steel fins provided to ensure better heat transfer.
  2. Hermetically sealed compressor CFC free compressor (134 A gas) coupled with evaporation coil and condenser.

Door & Gasket:

Robust type hinges fitted on the right hand side of the chamber with front opening single door. Leak proof double lined silicon gasket will be provided. The inner surface of the door will be provided with pre-polished stainless steel and will be mounted such that conduction is avoided.

Shaking Rack:

  1. Removable Stainless steel rack
  2. Adjustable in height
  3. Strong enough to withstand heavy load of test specimens
  4. Equipped with lotus clamps to accommodate 50 flasks of 500 ml capacity. (Without Flasks)

Electrical controls:

Relays, Contactors, SSR, MCB, Mains Switch, Fan control switch, compressor ON/OFF switch with indicator, Dry heater switch with indicator for safe and ease of operation.

Electrical Circuitry Wires:

Inner circuitry wires with individual number tags for ease of servicing and maintenance

Safety Provisions:

  1. Over temperature thermostat & thermal fuses provided for Heating system.
  2. Low water level boiler cut off
  3. Electrical overload cut off
  4. Time delay for compressor switch ON
  5. Electrical circuit breaker

Note:

For these range of Equipment, the installation and demonstration at site by our technician is a prerequisite for availing free servicing during the guarantee period of 12 months from the date of sale. On site demonstration is essential and mandatory to avail warranty claim. Warranty void in case on site demonstration not availed.

Pre - installation mandatory requirement: (Guarantee void in case of noncompliance):

  1. An operator shall maintain Room temperature around machine preferably at 25 °C with air conditioning system or shall arrange for a well ventilated room with exhaust fan. However, surrounding temperature should not exceed 30 °C
  2. Stabilized Input Voltage of 230 Volt, 50 Hz,  20 Amps, AC Supply must be available for error less performance of the instrument. Use of Servo Controlled Stabilizer is recommended.