PORTABLE PETROLEUM QUALITY ANALYZER-WITH PC SOFTWARE, USB CABLE AND TOOL BAG-(SXE-300)
Model Number : SXE-300
Detailed specification as follows.
PORTABLE PETROLEUM QUALITY ANALYZER-WITH PC SOFTWARE, USB CABLE AND TOOL BAG-(SXE-300)
| Petrol Octane Number | |
|---|---|
| Measured petrols octane numbers range | 40–125 ON |
| Acceptable limit of octane number measurement basic error, max | ± 0.5 ON |
| Limit of acceptable difference between parallel octane number measurements, max | ± 0.2 ON |
| Antiknock Additives Content in Petrol | |
| The determination range of antiknock additives content in petrols | 0.5-15 % |
| Acceptable basic error limit of antiknock additives content determination in petrols | 0.1 % |
| Petrol Oxidation Breakdown Time | |
| Petrol oxidation breakdown time measurement range | 50-2400 minutes |
| Acceptable basic error limit of petrol oxidation breakdown time | 5 % |
| Resistivity Measurement | |
| Petrol quality determination mode basing on volume resistivity | 10 raise to 6 - 10 raise to 14 om |
| Acceptable basic error limit of volume resistivity measurements | 3 % |
| Cetane Number | |
| Cetane numbers measurement range | 20–100 CN |
| Acceptable basic error limit of cetane numbers, max | ±1.0 CN |
| Acceptable difference limit between cetane numbers parallel measurements, max | ± 0.5 CN |
| Diesel Fuel Pour Point | |
| Acceptable error limit when determining diesel-fuel pour points | ± 2 °C |
| Kerosine content determination range in diesel fuels | 0-95 % |
| Mode for pour point depressants content determination for diesel fuel | 3 % |
| Acceptable basic error limit when determining kerosene content in diesel fuels | 0.2-1 % |
| Acceptable basic error limit when determining of pour point depressants content | 0.01 % |
| Motor Oil Clarity Level Measurement | |
| Motor oils clarity level measurement range | 95-100 % |
| Acceptable error limit of motor oils clarity level measurement | 0.1 % |
| Acceptable difference limit between motor oils clarity parallel measurements | 0.01 % |
| Di-Electric Permeability Measurement | |
| POL dielectric permeability measurement range | 1–5 Unit |
| Acceptable error limit of dielectric permeability measurement, max | 0.001 Unit |
| Acceptable difference limit between POL dielectric permeability parallel measurements, max | 0.001 Unit |
| Oil Base Number Determination | |
| Oils base number determination range | 0-24 Unit |
| Acceptable basic error limit when determining oils basic number | 1 BN unit |
| Circuit Breaker Oil Breakdown Time | |
| Circuit-breaker oils (dielectrics) breakdown voltage measurement range | 5–100 kV |
| Acceptable error limit of circuit-breaker oils breakdown voltage measurement, max | 1 kV |
| Acceptable difference limit between circuit-breaker oils breakdown time parallel measurements, max | 0.2 kV |
| Circuit Breaker Oil Loss Angle Tangent | |
| Measurement range of circuit-breaker oils loss angle tangen | 0.01–40 % |
| Acceptable error limit of circuit-breaker oils loss angle tangent, max | 0.01 % |
| Acceptable difference limit between circuit-breaker oils loss angle tangent parallel measurements, max | 0.001 Unit |
| Mechanical Impurities Content | |
| Determination range for mechanical impurities content in oil products | 97-100 % |
| Acceptable basic error limit when determining mechanical impurities content in oil products | 0.01 % |
| Water in Oil Content | |
| Water-in-oil content determination range for oil products | 0-30 % |
| Acceptable basic error limit when determining water-in-oil content of oil products | 1 % |
| Measurement Time | 1–5 s |
| Insufficient power supply indication operation threshold | 5.4 V |
| Instrument useful life | 6 |
| Overall Dimensions | |
| Electronic module | 211 x 100 x 45 mm |
| Sensor #1 and #2 | 60 х 100 mm |
| Weight | 850 Grams |