NABL Accredited Calibration Laboratory

BACTERIOLOGICAL INCUBATOR-DIGITAL-GMP-90X60X60 CM

Model Number : EIE-201DG324

Double walled, Inner chamber S.S. 304, Outer S.S.304, 65mm thick rock wool insulation, Polycarbonate sheet viewing window for test observation, Temp. range 5°C above ambient to 70°C 80/20 nichrome heating elements placed under ribs at bottom and sides for uniform heat distribution, Auto tune Dual Display. Digital temp. controller, forced air circulation, working on 230 V AC Single Phase. On site Validation at extra cost.

CONTROLLING SYSTEM

Salient Features:

  1. Exterior boy is fabricated from S.S. 304 Material
  2. Interior chamber is fabricated from Mirror polished Stainless Steel S.S. 304 Material
  3. Metal door with sponge - type silicon gasket for air-tight sealing
  4. Electrical wiring as per CE compliance
  5. Electric Motor located at the back side of unit, which is protected with safety cover to avoid accident
  6. User friendly and tactfully designed chamber door and locking mechanism
  7. Aesthetic outer appearance and high quality
  8. Unit mounted on castor wheels for easy movement.
  9. Supplied complete with Stainless Steel Trays for sample placement
  10. IQ, OQ, PQ, DQ Documentation available at extra cost

Air Circulation:

Temperature is maintained by a quiet running blower for better air circulation throughout the chamber. Forced air circulated vertically down and re-circulated throughout the chamber for uniform temperature distribution.

Heating System:

Long lasting heaters used as heating element.

Trays for samples:

  1. Trays of the incubator will be manufactured from strong Stainless steel rods - strong enough to with-stand heavy load of test specimens, which should be equally distributed among trays.
  2. Such trays will also facilitate better air circulation.
  3. The distance between trays will be 15-20 centimeters.

Safety Features:

  1. High temperature safety cut off (Thermostat)
  2. Electrical overload safety (Fuse 10 Amperes) 

Pre installation mandatory requirement : (Guarantee void in case of non compliance):

a) An operator shall maintain Room temperature around machine preferably at 25 °C with air conditioning system or shall arrange for a well ventilated room with exhaust fan. However, surrounding temperature should not exceed 30 °C .

b) Stabilized Input Voltage of 230 Volt, 50 Hz, 20 Amps, AC Supply must be available for error less performance of the instrument. Use of Servo Controlled Stabilizer is recommended.