HIGH PRESSURE CYLINDRICAL HORIZONTAL STERILIZER-SINGLE DOOR -MANUAL -24"X43"
Model Number : EIE-208SMO303
TYPE OF DOOR
- DOUBLE HINGED DOOR / FULLY AUTOMATIC / 16 X 24 INCH
- DOUBLE HINGED DOOR / FULLY AUTOMATIC / 20 X 36 INCH
- DOUBLE HINGED DOOR / FULLY AUTOMATIC / 20 X 48 INCH
- DOUBLE HINGED DOOR / FULLY AUTOMATIC / 20 X 60 INCH
- DOUBLE HINGED DOOR / MANUAL / 18 X 30 INCH
- DOUBLE HINGED DOOR / MANUAL / 20 X 36 INCH
- DOUBLE HINGED DOOR / MANUAL / 24 X 36 INCH
- SINGLE HINGED DOOR / FULLY AUTOMATIC / 16 X 24 INCH
- SINGLE HINGED DOOR / FULLY AUTOMATIC / 16 X 44 INCH
- SINGLE HINGED DOOR / FULLY AUTOMATIC / 20 X 36 INCH
- SINGLE HINGED DOOR / FULLY AUTOMATIC / 20 X 48 INCH
- SINGLE HINGED DOOR / FULLY AUTOMATIC / 20 X 60 INCH
- SINGLE HINGED DOOR / FULLY AUTOMATIC / 24 X 43 INCH
- SINGLE HINGED DOOR / MANUAL / 16 X 24 INCH
- SINGLE HINGED DOOR / MANUAL / 20 X 36 INCH
- SINGLE HINGED DOOR / MANUAL / 20 X 48 INCH
- SINGLE HINGED DOOR / MANUAL / 24 X 36 INCH
- SINGLE HINGED DOOR / MANUAL / 24 X 43 INCH
Door Safety Features
Following door safety features are provided for maximum operator safety
(1) Process-lock to prevent opening of the door during the process.
(2) Process-lock to prevent opening of the door after successful completion of the test cycle.
Insulation
The gap between the sterilization chamber and outer jacket will be heavily insulated with minimum of 50-mm thick R. B. Glass Wool material to avoid thermal leakage
Piping Package
All process piping in contact with the chamber will be fabricated from SS-304 grade material with argon welding.
Steam Accessories
The jacket and chamber are provided with an over pressure safety valve. The jacket is provided with a steam trap.
Surface Finish
The inside surface of the chamber and doors are finished to a surface finish better than 0.8 Ra value. All other non-contact parts are polished to a surface finish better that 180 grit.
Temperature and Pressure Gauge
- One TEMPERATURE SENSOR will be provided; - Fitted at drain outlet. Inputs/outputs of all sensors and electronic parts are monitored, processed and controlled by Microprocessor based PID Controller for accurate data processing.
- A pressure gauge is connected with the inner chamber to indicate the steam pressure.
Electrical Switchgear
The control cabinet to be provided with a main isolator for the three-phase supply and a separate switch for the control supply. The fascia of the control panel is provided with indication LED’s and switches for operation. Switchgear make : Schneider
Requirement at buyer end
Water supply provision for steam generator.
| Type | Horizontal Steam sterilizer, Single door, Cylindrical Type |
|---|---|
| Working Chamber Size | 24” x 43” (4 drum capacity) |
| Chamber volume | 310 Liters |
| Inner Chamber thickness | 3 mm |
| Jacket thickness | 2 mm |
| Chamber working Pressure | 2.5 kg/cm2 |
| Jacket working Pressure | 2.5 kg/cm2 |
| Hydro test (Pressure chamber) | 3.5 Kg/Cm2 |
| Hydro test ( jacket) | 4.0 Kg/cm2 |
| Inner Chamber | Fabricated from Mirror polished Stainless Steel Material S.S. 304 Grade |
| Jacket | Fabricated from mirror polished stainless steel material S.S. 304 Grade |
| Operating Temperature | 121°C |
| Door | Fabricated from stainless steel material S.S.304 grade |
| Door gasket | Silicon Door Gasket (Food grade) |
| Door gasket size | 12” x 12” |
| Hinge & Locking Rod | Mild steel Material |
| Central Locking parts | C.I.Casing, Wrinkle black painted |
| Shooting Bolts | Tempered, chrome plated |
| Stand | M.S. Round Pipe |
| Operation | Manual cycle |
| Tempe Indication | Microprocessor based PID digital temperature controller & indicator |
| Temperature Accuracy | 0.10°C |
| Pressure Indication | Analogue pressure gauge |
| Pressure least count | 0.2 PSI |
| Heating | 2 Industrial immersion heaters each of 9 Kw |
| Other accessories | Steam trap, pressure switch, float switch , Temp Sensor , Pressure Gauge , Temp Gauge , Non return valve , solenoid valves , Vacuum Venture |
| Wheels | Castor Wheel on all 4 stands |
| Documents | Operation & Maintenance Manual (SOP) DQ / IQ / OQ / PQ |
| Safety features | Safety valve, safety cut off device. |
| Multi port valve | For controlling sterilization cycle |
| Steam Generator | Cylindrical shape steam generator made of S.S. 304 Material, Will be attached to underneath the jacket. It will be fitted with ISI marke |
| Operation on | 230 Volts, 50 Hz, Single Phase, AC Supply |