AUTOCLAVE FOR SANITARY WARE-
Compliance with following International Standards - ISO - 10545 (Part 9), IS - 13630.
REFLECTANCE METER / WHITENESS METER-
Principles - Whiteness is property of Luminous Objects. Whiteness is measured in terms of diffuse Reflectance, which is the ratio of reflected light measured at 90° after passing through a suitable filter and the incident light that is generally at 45° to the surface of the sample. With 45° Diffuse Reflectance head for whiteness and brightness measurement. This Instrument is Filter less - 2 colors wavelength provided on selectable switch with long life secondary standard.
BULK DENSITY APPARATUS FOR GREEN CERAMIC TILES-(MERCURY METHOD)
Complete with mercury (2 kg) and Electronic weighing Balance(10 kg X 0.1 gm).
DETERMINATION OF FROST RESISTANCE-(BIS 13630-10, EN ISO 10545-12)
Compliance standards: EN ISO 10545-12, ASTM C1026, IS 13630 (Part-10), Suitable for tile size up 500 X 500 mm.
DILATOMETER-(DETERMINATION OF LINEAR THERMAL EXPANSION)-1000 °C-(ISO 10545-8)
A dilatometer is an instrument used to measure the linear thermal expansion of materials when subjected to temperature changes. In compliance with ISO 10545-8, this test is specifically designed for ceramic tiles to determine their thermal expansion characteristics up to 1000°C.
APP FOR MEASUREMENT OF SURFACE FLATNESS WARPAGE (BIS 13630 PART 1) (EN 10545-2)-(1300 X 1300 MM)
Suitable to measure tile size up to 1300 x 1300 mm, complete with 5 Nos. Digital dial gauge of 0.001mm X 10mm, Aluminium Master Calibration Plates. PC software and data acquisition system available at extra cost.
MOR TESTING MACHINE-1000 KGF-UP TO 60 X 60 CM TILES-SERVO CONTROLLED (BIS 13630 PART 6, ISO 10545-4)
IS: 13630 (Part - 6), ISO 10545 (Part-4)
DETERMINATION OF MOISTURE EXPANSION USING BOILING WATER FOR UNGLAZED TILE-(BIS 13630-3, EN ISO 10545-10) WITH ACCESSORIES
As per IS:13630 (Part 3). Complete with Digital Vernier Caliper 300 mm, Dessicator of 300 mm dia, Length Comparator with standard reference bar and 1 kg silica gel.
BALL RELEASE FOR IMPACT RESISTANCE OF TILES-(BY MEASUREMENT OF COEFFICIENT OF RESTITUTE)-(BIS 13630 PART 14, ISO 10545-5)
The Ball Release for Impact Resistance of Tiles (by measurement of the coefficient of restitution) is covered under EN ISO 10545-5 and IS 13630 (Part 14). The test evaluates the impact resistance of ceramic tiles by measuring the coefficient of restitution of a steel ball dropped from a specified height onto the tile surface.
WET TRANSVERSE STRENGTH TESTING MACHINE IS 13801-ANNEX F
The equipment complies with the requirements of: IS 13801 – Annex F and IS 1237 – Annex F. Also available as per ASTM C1167 (Roofing Tiles – Transverse Strength) and EN 538 (Clay Roofing Tiles – Flexural Strength)
DETERMINATION OF RESISTANCE TO THERMAL SHOCK-LIQUID TO AIR-20 C TO 170 C-
Liquid-to-air thermal shock testing exposes samples to extreme temperature changes, causing stress from material expansion and contraction. This leads to fatigue, cracking, and coating failure. While effective for detecting weaknesses, it may not reflect real-world conditions, so results should be interpreted with caution and supplemented with other tests.
APP FOR MEASUREMENT OF SURFACE FLATNESS AND WARPAGE (BIS 13630 PART-1) (EN ISO 10545-2)-(300 X 300 MM)
Suitable to measure tile size up to 300 x 300 mm, complete with 5 Nos. Digital dial gauge of 0.01 mm X 25 mm, Aluminium Master Calibration Plates. PC software and data acquisition system available at extra cost.
LOAD TESTING MACHINE - 1000 KGF - FOR WC / WASH BASIN
It is mainly used for testing the load-bearing performance of toilet, basin. The load-bearing testing machine is composed of PLC, servo motor, LOAD CELL and other control components and program to test WC.
HYDRAULIC PRESS - 25 TON - AUTOMATIC
This is electrically operated version of the manual press. The pumping is done by gearmotor drive. Simply press a button & it will start building pressure & will stop automatically at set pressure by means of a pressure switch. Evacuable die set available at extra cost
PORTABLE TOUCH SCREEN HMI BASED - PREMIUM REFLECTANCE METER / WHITENESS METER
Principles - Whiteness is property of Luminous Objects. Whiteness is measured in terms of diffuse Reflectance, which is the ratio of reflected light measured at 90° after passing through a suitable filter and the incident light that is generally at 45° to the surface of the sample. With 45° Diffuse Reflectance head for whiteness & brightness measurement. This Instrument is Filter less - 2 colors wavelength provided on selectable switch with long life secondary standard.
HIGH TEMP. FURNACE-12" X 8" X 8"-1500°C
The High Temperature Furnace is a table-top type laboratory furnace designed for continuous operation up to 1400°C and intermittent operation up to 1500°C. The unit is suitable for high-temperature heat treatment, sintering, calcination, ceramic processing, refractory testing, material research, and laboratory applications requiring precise temperature control and uniform heating conditions.