ASPHALT MIXER-THEORETICAL DENSITY METER-WITH VACUUM PUMP-WITH VIBRATING TABLE-WITH METAL CONTAINER
This equipment is used for determination of theoretical density of asphalt mixer by vacuum method for application such as asphalt mixer design, road condition investigation, calculation of porosity and compactness in road construction quality management.
DUAL CHAMBER-COMBINED BOD CUM BACTERIOLOGICAL INCUBATOR-GMP-DIGITAL-60 X 60 X 60 CM-216 LITERS CAPACITY
Double walled, inner chamber S.S.304, Outer chamber also S.S. 304 , 65 mm thick glass wool & PUFF insulation , 80/20 nichrome heating elements placed under ribs at bottom and sides for uniform heat distribution Temp. Range. 5˚C to 60˚C for BOD Incubator and 5˚C above ambient to 70˚C for Bacteriological Incubator, Auto tune Dual Display Digital, forced air circulation, Working on 230 Volts AC Single Phase.
DUAL CHAMBER-COMBINED REFRIGERATOR CUM DEEP FREEZER-GMP-HMI, PLC & 21 CFR SOFTWARE-60 X 60 X 60 CM-216 LITERS CAPACITY
Double walled, inner chamber S.S.316, Outer body is also fabricated from S.S. - 304 Material, 65-75 mm thick puf insulation, Temp. Range. 2˚C to 8˚C for refrigerator and Temp. Range. -10˚C to -20˚C for freezer, Chamber equipped with PLC & Touch screen HMI display, forced air circulation for refrigerator, Working on 230 Volts, Single Phase, AC Supply
APPARATUS FOR DISTILLATION OF EMULSIFIED ASPHALT - (WITH ELECTRIC BURNER) - (ASTM D244, ASTM D6997) - WITH ACCESSORIES
Use of this set will allow the user to accurately determine the representative portion of residue in emulsified asphalts. Used to examine the asphalt emulsions composed principally of a semi-solid or liquid asphaltic base, water and an emulsified agent.
GMP Twin Chamber With HMI, PLC & 21-CFR Software
Double walled, inner chamber S.S.304, Outer body is also fabricated from S.S. - 304 Material, 65-75 mm thick puf insulation, Temp. Range. 2˚C to 8˚C for refrigerator and Temp. Range. -10˚C to -25˚C for freezer, Chamber equipped with PLC & Touch screen HMI display, forced air circulation for refrigerator, Working on 230 Volts, Single Phase, AC Supply
DUAL CHAMBER-COMBINED REFRIGERATOR CUM DEEP FREEZER-GMP-HMI, PLC & 21 CFR SOFTWARE-60 X 45 X 45 CM-121 LITERS CAPACITY
Double walled, inner chamber S.S.316, Outer body is also fabricated from S.S. - 304 Material, 65-75 mm thick puf insulation, Temp. Range. 2˚C to 8˚C for refrigerator and Temp. Range. -10˚C to -20˚C for freezer, Chamber equipped with PLC & Touch screen HMI display, forced air circulation for refrigerator, Working on 230 Volts, Single Phase, AC Supply
ABSOLUTE AND KINEMATIC VISCOSITY BATH-SEMI AUTOMATIC
As per IS: 1206 (Part II and III).Supplied complete with Viscosity bath with built in PLC,HMI and digital vacuum controller with Vacuum Pump -capable to maintain vacuum of 300 mm/Hg, Indian Make Vacuum Manning Viscometer No.12 and 13, Reverse flow Viscometer No.6 with certificate of constant and calibration certificate for Viscosity bath, Complete with instruction manual. Detailed Specification as mentioned in technical part mentioned below. Canon USA Make Glass U Tube Viscometer, Mercury Manometer, Silicon oil, silicon tubes etc. are available at extra cost
BENDING BEAM RHEOMETER
This instrument is made and designed as per ASTM D6648, BS EN 14771, AASHTO T313. Complete with PC and software but without air compressor and Bath fluid (available at extra cost)
LOAD TESTING MACHINE - 1000 KGF - FOR WC / WASH BASIN
It is mainly used for testing the load-bearing performance of toilet, basin. The load-bearing testing machine is composed of PLC, servo motor, LOAD CELL and other control components and program to test WC.
AIR JET SIEVING MACHINE - EIE-AIR-200
Supplied without air jet sieves, Vacuum system and Electronic weighing balance
PRECISION ELECTRONIC BALANCE -(4200 GM)-(0.01 GM (10 MG))-(EXTERNAL CALIBRATION) SAB-4202-CL
Capacity : 4200gm, Least count 0.01gm, Big LCD Display with Back Light for easy view, IR Sensor for TARE CAL Function, Auto Zero Tracking Faction, 4 Units Available: g, ct, lb, oz, Response time within 5 Second, Standard Bi-Directional RS232 Interface. External Calibration by one touch key
DUAL CHAMBER-COMBINED REFRIGERATOR CUM DEEP FREEZER-GMP-HMI, PLC & 21 CFR SOFTWARE-60 X 60 X 60 CM-216 LITERS CAPACITY
Double walled, inner chamber S.S.316, Outer body is also fabricated from S.S. - 304 Material, 65-75 mm thick puf insulation, Temp. Range. 2˚C to 8˚C for refrigerator and Temp. Range. -10˚C to -25˚C for freezer, Chamber equipped with PLC & Touch screen HMI display, forced air circulation for refrigerator, Working on 230 Volts, Single Phase, AC Supply
AUTOMATIC FRAASS BREAKING POINT TESTER
This instrument is used to determine the temperature which a bitumen tends to break rather to flow when cooled and stressed . It can do three tests at the same time in the same environment and calculate the average value.The cooling rate is controlled by computer. It is controlled by micro computer. The cooling rate is controlled automatically. It has automatically timing to bend samples.The test data is shown on the colored LCD and output on built-in printer. Supplied complete with Automatic Breaking Point Tester, Low temp.cyclic Thermostatic bath, Stainless steel sample piece(6 Nos.) and necessary rubber tubings. Other necessary Instruments Viz. Hot Plate, Furnace, Weighing Balance and solvents etc.
AGGREGATE IMPACT TESTING MACHINE WITH BLOW COUNTER (BS - 812)-
Complies with following International Standards : NF P18-574, BS 812. Purpose - For determining the aggregate impact value of coarse aggregate. This test method provides a relative measure of the resistance of an aggregate to sudden shock or impact.
FLUX OVEN - 110 KG
ESAB’s drying & re-drying ovens for Electrodes and SAW ux provides uniform heating through well dispersed multiple heating elements. Thick glass wool thermal insulation ensures heat retention and efficient utilization of energy.User friendly controls with simple knobs for portable ovens and digital control panels & display for the bench and ux ovens reduce operator fatigue. The Flux ovens are designed for top loading and bottom dispensing with slag screen that acts as a sieve to lter out contaminants and to protect the heating elements.
VACUUM DEGASSING OVEN
The Vacuum Degassing Oven (VDO) from ATS has been designed to degas pressure aged binder samples to precisely and accurately meet AASHTO R28-06 and ASTM D6521-05 standards.
M.B.R.T. BATH
Double walled, Inner chamber S.S.304, Outer G.I.Powder coated, Digital temp.controller, with Motorized stirrer and S.S.platform for placing the Test Tube Rack. Supplied complete with a Test Tube rack to place 40 MBRT test tubes at a time. MBRT test may be utilized for grading of milk which may be useful for the milk processor to take a decision on further processing of milk. As per BIS 1479 (Part 3): 1977.
VACUUM DEGASSING OVEN - WITH VACUUM PUMP & PLC, HMI CONTROL SYSTEM - ASTM D6521
The Vacuum Degassing Oven (VDO) from EIE has been designed to degas pressure aged binder samples to precisely and accurately meet AASHTO R28-06 and ASTM D6521-05 standards.
FLUX DRYING OVEN-50 KG
Oven with Control Panel & 6 Nos. Wire mesh Angle Frame Trays {Size: 3ft x 2ft x 2ft – Rating: 12 KW; Motor: 1/2 HP-01 Nos. Capacity: 50 kg